what is the difference between IPX9 & IPX9K Ratings?
From: BONAD  Date: 2024-03-13 10:24:15


What does it mean of the IPX and IPX9K?

K" refers to the test band pressurisation requirements, IPX9K test pressure needs to reach 10,000Kpa, and then extended to other levels of protection with K, such as 4K, 6K, in fact, all have pressure requirements.

IPX9 and IPX9K are both standard IP enclosure waterproof grade, both of them meet the requirements of international standards ISO20653-2013, VW80000, Article 14.2.9 in GB/T4208-2017 and Fig. 7, Fig. 8, Fig. 9, Fig. 10, Fig. 11, Fig. 12 waterproof grade IPX9/9K. Among them, IPX9 is without increased pressure, while IPX9K is high temperature and high pressure spray test.

Degrees of protection against water

Table 4 contains short descriptions of the degrees of protection with the relevant requirements.

The degrees of protection 1 to 6K for the protection against water always include the preceding degrees of protection. Due to different physical effects, this does not apply automatically for the degrees of protection against water 7. 8 and 9K.

Should this apply nevertheless, the included lower degree of protection shall be indicated separately, e.g.IPX4K/IPX7.IPX5/IPX7.IPX6K/PX8 or IPX6K//IPX9K.

Degrees of protection against water

Second code element

Degree of protection

Brief description

Requirements

0

Not protected

None

1

Water drips vertically

Vertical drips shall not have any harmful effects or impair performance.

2

Water drips with enclosure inclined by 15°

Vertical drips shall not have any harmful effects or impair performance when the enclosure is tilted at any angle up to 15° on either side of the vertical.

3

Water spray

Water spray at an angle up to 60° on either side of the vertical shall have no harmful effects or impair performance.

4

Splash water

Water which splashes against the enclosure from any direction shall not have any harmful effects or impair performance.

4K

Splash water with increased pressure

Water which splashes against the enclosure from any direction with increased pressure shall not have any harmful effects or impair performance.

5

High-velocity water

Water which is directed against the enclosure from any direction as a jet shall not have any harmful effects or impair performance.

6

Strong high-velocity water

Water which is directed against the enclosure from any direction as a strong jet shall not have any harmful effects or impair performance.

6K

Strong high-velocity water with increased pressure

Water which is directed against the enclosure from any direction as a strong jet with increased pressure shall not have any harmful effects or impair performance.

7

Temporary immersion in water

Water shall not penetrate in a quantity causing harmful effects or impair performance if the enclosure is immersed in water temporarily under specified pressure and time conditions.

8

Continuous immersion in water

Water shall not penetrate in a quantity causing harmful effects if the enclosure is continuously immersed in water under conditions which shall be agreed between supplier and car manufacturer, but which are more severe than code 7.

9K

Water during high-pressure/steam-jet cleaning

Water which is directed against the enclosure from any direction shall not have any harmful effects or impair performance.


IPX9 AND IPX9K RATINGS – MEANING AND TESTING CONDITIONS

As explained in the introduction, IPX9 and IPX9K ratings guarantee protection against high-pressure, high-temperature water jets. The testing conditions for IPX9 and IPX9K ratings are precisely defined by the IEC and ISO.

When small devices are tested, they are put on a rotating stand inside a testing chamber. The rotation speed is 5rpm. For large devices, the IEC standard allows tests in an open space (outside the testing chamber).

For both standards, the water temperature is set at 80°C (±5°C). The distance between the device and the spray nozzle is 100-150mm. For large enclosures, the IEC allows a distance of 175mm ±25mm.

Small devices are sprayed from 4 positions/angles (0°-30°-60°-90°), measured from the horizontal axis. Large devices are sprayed from all angles.

Water pressure is 8-10 MPa, and the volume is 15 l/min.

The test duration is 30sec per position for small devices or 1min per m2 for large devices. The minimal test duration for large devices is 3 minutes.

IPX9 and IPX9K Testing Conditions

Testing Conditions

IPX9

IPX9

IPX9K

Small Enclosures

Large Enclosures

Water Temperature

80°C (± 5°C)

80°C (± 5°C)

80°C (± 5 °C)

Distance

100-150mm

175mm ± 25mm

100-150mm

Angle

0°/30°/60°/90°

All directions

0°/30°/60°/90°

Turntable Speed

5rpm (± 1rpm)

N/A

5rpm (± 1rpm)

Water Pressure

8-10 MPa

8-10 MPa

8,000-10,000 kPa

Water Flow Rate

15 l/min (± 1 l/min)

15 l/min (± 1 l/min)

14-16 l/min

Test Duration

30sec per position

1 min per m2 (at least 3min)

30sec per position

The marking of an enclosure with the Ip code IPX34K means:

[IPX3] Protection of the electrical equipment access to the enclosure against foreign objects with adiameter of more than 2,5 mm (protection against foreign objects), and protection of persons handling rods of 2,5 mm diameter or more against access within the enclosure(protection against access).

(IPX4K) Protection of electrical equipment within the enclosure against harmful effects resulting from water splashing against the enclosure with increased pressure from any direction (pro-tection against water)

The marking of an enclosure with the lP code lP16KB means:

(IPX1)Protection ofthe electrical equipment within the enclosure against foreign objects with adiameter of more than 50 mm(protection against foreign objects).

(IPX6K) Protection of electrical equipment within the enclosure against harmful effects resulting from water directed against the enclosure from any direction as a strong jet with increased pressure(protection against water).

Protection of persons against finger contact with hazardous parts within the enclosure (pro-tection against access).


 
 
Home  |  Products  |  News  |  About us  |  Feedback  |  Contact us  |  
Copyright © 2008-2015 Hong Kong Bonad Technology Limited | Shenzhen Bonad Instrument Co., LTD. All Rights Reserved.
 
    Add:C505, Hongdu Building,Bao\\\'an45 district,Shenzhen,518101,Guangdong Province,China    Tel:+86-13380391156    Fax:0755-23721200    Email:Alice@szbonad.com
 
好吊色免费在线观看视频| 精品人妻一区二区三区四区久久| 天堂热东京热男人天堂| 99久热只有精品视频最新| 国产一区欧美午夜福利| 日本一区不卡在线观看| 精品久久久一区二区三| 亚洲欧洲成人精品香蕉网| 日韩一级免费中文字幕视频| 日韩三级黄色大片免费观看| 日韩一区二区三区免费av| 亚洲乱码av中文一区二区三区| 国产免费人成视频尤物| 亚洲成人免费天堂诱惑| 91超精品碰国产在线观看| 国产成人精品国产成人亚洲| 国产日韩欧美国产欧美日韩| 丰满人妻熟妇乱又乱精品古代| 国产传媒免费观看视频| 久久亚洲午夜精品毛片| 熟妇久久人妻中文字幕| 日本一本在线免费福利| 丝袜视频日本成人午夜视频| 国产丝袜女优一区二区三区| 亚洲一区二区三区在线中文字幕| 日本高清加勒比免费在线| 中文字幕欧美精品人妻一区| 国产成人精品国产亚洲欧洲| 成人综合网视频在线观看| 人人爽夜夜爽夜夜爽精品视频| 视频在线播放你懂的一区| 欧美日韩欧美国产另类| 99久久国产精品亚洲| 亚洲中文字幕三区四区| 亚洲男人天堂网在线视频| 国产精品一区二区成人在线| 日韩人妻欧美一区二区久久| 国产精品日本女优在线观看| 欧美一区二区三区99| 久久99国产精品果冻传媒| 亚洲精品中文字幕在线视频|